What Happens if an EICR Fails?

What happens if an EICR fails in Manchester property

If an EICR fails, it means the report has come back unsatisfactory because the electrician has identified one or more observations coded C1, C2 or FI. For landlords, that usually means remedial work or further investigation needs to be arranged without delay. For homeowners and buyers, it means the installation has safety issues that need dealing with properly before the report can be considered resolved.

The important thing to know is that a failed EICR does not automatically mean you need a full rewire. In many cases, the problems can be dealt with through targeted remedial works such as improving bonding, replacing damaged accessories, correcting faults or upgrading an outdated consumer unit.

Quick answer

An EICR fails when the report is marked unsatisfactory.

This normally happens because the report includes:

  • C1 – danger present
  • C2 – potentially dangerous
  • FI – further investigation required without delay

A C3 does not fail an EICR. It means improvement is recommended, but the overall report can still be satisfactory.

Who this applies to

This guide is useful for:

  • landlords
  • homeowners
  • homebuyers
  • letting agents
  • business owners
  • property managers

If you have received an unsatisfactory report and are unsure what to do next, the key is not to panic. The next step is to understand the codes, what the electrician has actually found, and what remedial work is required.

What counts as a failed EICR?

A failed EICR is usually referred to as an unsatisfactory EICR.

That means the electrician has recorded one or more issues serious enough to affect the overall outcome of the report.

C1 – danger present

A C1 means there is immediate danger and urgent action is required. In some cases, the electrician may make the issue safe there and then, if it is possible to do so safely and with agreement.

C2 – potentially dangerous

A C2 means the issue is not necessarily causing immediate danger at that exact moment, but it is still serious enough that urgent remedial work is needed.

FI – further investigation required

An FI means the electrician has identified something that needs more investigation without delay before the installation can be considered satisfactory.

C3 – improvement recommended

A C3 does not fail the EICR. It means an improvement is recommended, but the installation can still receive a satisfactory outcome if there are no C1, C2 or FI observations.

For a broader guide to inspection reports, you can also read What Is an EICR?.

Common reasons an EICR fails

A failed EICR can happen for a range of reasons, but some of the most common include:

  • lack of RCD protection where it is required
  • poor earthing or bonding
  • damaged sockets, switches or accessories
  • signs of overheating or burning
  • exposed live parts
  • unsafe DIY electrical work
  • incorrect protective devices
  • faults that need further investigation
  • an outdated or unsafe consumer unit

It is worth remembering that an EICR is there to assess whether the installation is safe for continued use, not simply whether it looks old.

What happens next after a failed EICR?

The next step depends on what the report actually says, but in most cases the process looks like this.

1. Review the observations properly

Start by looking at the codes and reading the observations clearly. A C1, C2 and FI do not all mean the same thing, so the report needs to be understood properly before deciding what happens next.

2. Book in remedial works or further investigation

If the report is unsatisfactory, the relevant remedial works or investigation should be arranged as soon as possible.

For rental properties, this is especially important because the report may trigger legal duties around timescales and written confirmation.

3. Keep a proper record

You should keep:

  • the original EICR
  • any remedial certificates
  • any further investigation paperwork
  • any written confirmation that the work has been completed

4. Make sure the right follow-up documents are issued

Depending on the work carried out, this could include a Minor Electrical Installation Works Certificate, an Electrical Installation Certificate, or written confirmation linked to the original EICR.

If your report has come back unsatisfactory, the next step is to get clear advice and the right remedial work booked in. If you are renting out a property, our Landlord EICR in Manchester service is the best place to start.

Common remedial works after a failed EICR including consumer unit upgrades

Do you need a full rewire if an EICR fails?

Usually, no.

A failed EICR does not automatically mean the property needs rewiring. In many cases, the issues can be sorted through targeted remedial works rather than a full rewire.

That might include:

  • replacing damaged accessories
  • correcting bonding issues
  • improving RCD protection
  • replacing unsafe components
  • upgrading a consumer unit
  • carrying out further investigation on one circuit or area of the installation

If the report highlights problems with an outdated board or protective devices, a Consumer Unit / Fuse Board Upgrade may be the most appropriate next step.

How long do landlords have to fix a failed EICR?

For landlords in England, if the report requires remedial work or further investigation, it generally needs to be carried out within 28 days, or sooner if the report specifies a shorter period. Landlords must then obtain written confirmation from a qualified person and provide that confirmation, together with the original report, to tenants and to the local authority if requested.

Can tenants stay in a property if the EICR fails?

That depends on the faults identified.

A failed EICR does not automatically mean a property has to be vacated, but some observations are more serious than others. A C1 indicates danger present, which can require immediate action to make the situation safe. A C2 also requires urgent remedial work. The right response depends on the actual condition found during the inspection.

What should buyers and homeowners do after a failed EICR?

If you are buying a property and the EICR comes back unsatisfactory, use the report to understand:

  • what is dangerous now
  • what is potentially dangerous
  • what needs further investigation
  • what is simply recommended improvement

A failed EICR can often help with negotiations, budgeting and planning the next stage of works. If you are arranging an inspection before purchase, our Homebuyer EICR in Manchester page is the most relevant next step.

What about commercial properties?

For commercial properties, a failed EICR should be treated seriously because it can affect safety, compliance, insurance expectations and business continuity. The right next step is to review the observations, prioritise urgent items and arrange any follow-up works without delay.

If your report relates to a workplace, office, shop, warehouse or other business premises, see our Commercial EICR in Manchester service.

FAQs

Does a C3 fail an EICR?

No. A C3 means improvement is recommended, but it does not make the report unsatisfactory on its own.

No. Many failed EICRs are resolved through targeted remedial works rather than a full rewire.

C2 means a potentially dangerous condition has been identified and urgent remedial work is required. FI means further investigation is required without delay before the installation can be considered satisfactory.

Usually within 28 days, unless the report specifies a shorter period.

Yes, provided the contractor is competent and the necessary work is properly certified where required.

Need help after a failed EICR? We carry out landlord, homebuyer and commercial inspections, as well as remedial works including consumer unit upgrades. Book online here to arrange your inspection or request a quote.


Find Us

Get Directions